Settings → SIEM Export decides where detections and events leave the appliance, how their severity is scored, and how much volume each destination receives. The same page holds the ITSM handoff, which posts compliance findings to your ticketing system as they open, change and close.
What do I need?
- Licence
- Enterprise
- Role
admin_user
Prerequisites
- An Enterprise licence. Every route on this page is gated on the integrations.siem capability and answers 403 FEATURE_NOT_LICENSED without it.
- You sign in as superadmin. The dashboard lists this pane only for superadmin and for the read-only viewer role, although the API accepts admin_user.
- A collector that accepts syslog on a known host and port, or an HTTPS endpoint that accepts a JSON POST.
- The appliance can reach that collector — see Network prerequisites.
- For a signed webhook: a shared secret your receiver can verify HMAC-SHA256 with.
/assets/screenshots/settings-siem-export@0.4.pngWhat is exported, and what never is
Only metadata leaves the appliance: entity types and counts, never prompt text and never a detected value. The dialog states this before you fill anything in.
A destination subscribes to streams:
| Stream | The page calls it | What it carries |
|---|---|---|
detections | Detections — every policy hit | Every policy hit, across chat, browser and SWG inspection, the extension and documents. |
security_events | Security events — blocks, auth failures, errors | Event log rows in the security and error categories. |
audit_events | Audit events — admin changes, review decisions | Event log rows in the audit category. |
findings | — | Compliance findings. ITSM destinations only; a SIEM destination cannot subscribe to it, and an ITSM destination cannot subscribe to anything else. |
Add a syslog destination
Open the export settings
Select Settings → SIEM Export, then Add destination.
The dialog opens on New destination.
Choose syslog
Set Destination type to Syslog (CEF / JSON).
The host, port, protocol and format fields appear.
Address the collector
Set Host, Port and Protocol — udp, tcp or tls.
TCP and TLS frame one event per line and time out after ten seconds. UDP is fire-and-forget: only a local socket error is ever reported.
Choose the wire format
Set Format to cef, json or ocsf.
CEF is the default and the most compact. OCSF is JSON, so each event is roughly 3.8 times the size of the same event in CEF — the page states the measured figures. On a per-EPS licence nothing changes, because the event count is identical.
Subscribe to streams
Select the streams under Streams.
At least one is required.
Choose the severity model
Set Severity model to Legacy (as shipped) or v2 — residual risk.
Under v2, severity tracks what is still exposed: a detection that was only flagged and reached the model scores higher than one that was blocked. New destinations are created on v2.
Save and test
Select Save, then Send test on the new row.
A toast reports Test event delivered, and a single synthetic event with the signature CID_TEST_EVENT arrives at your collector in the destination's real format.
Warning
Switching the severity model changes what the numbers mean. An alert rule keyed on a threshold matches different events afterwards. Review those rules in your SIEM before you save.
Add a signed webhook destination
Choose the webhook type
Select Add destination and set Destination type to Webhook (JSON batch).
Enter the endpoint
Set URL to an http:// or https:// endpoint.
The appliance POSTs there with a ten-second timeout and follows no redirects. Anything outside the 2xx range is a failure.
Set the shared secret
Enter a value in Shared secret (HMAC).
Each request then carries X-CID-Signature as sha256= followed by the hex HMAC-SHA256 of
the exact request body. Leave it blank and no signature header is sent. Once stored, the field
shows stored — leave blank to keep.
Save and test
Select Save, then Send test.
Your endpoint receives one POST whose body is {"events":[…]} with a single test event
inside, plus the headers X-CID-Event-Count and, when a secret is set, X-CID-Signature.
Control how much a destination receives
Volume discipline is per destination, under What this destination receives.
| Control | Effect |
|---|---|
| Tier A — forward each event | Blocks and rejections on any channel, jailbreak and injection attempts, high-severity data that reached the model, and inspection bypasses. On by default. |
| Tier B — hourly summary per tenant | Masked and flagged volume as one event per tenant per hour, with a channel breakdown, unique users and the change against the previous hour. On by default. |
| Agent activity (Claude Code / MCP) | Counts of which agent tools ran and against which repositories, added to the hourly summary. Off by default — it is the largest stream the gateway produces. |
| Severity floor (1-10) | Events scoring below it are not forwarded and are counted as suppressed. The hourly summary is never muted by the floor. |
| Event types (opt-in) | A comma-separated allowlist. Empty means every type. It applies only to the security and audit streams. |
| Tenants / Tenant groups | Forward only these. Select nothing to forward every tenant. Group membership is re-resolved every export cycle. |
Tier C — clean traffic, heartbeats, and flags with nothing behind them — is never sent. It stays queryable in All detections.
Danger
A scoped destination stops receiving traffic that could not be attributed to a tenant, which includes unattributed SWG inspection traffic. Changing the scope re-seeds the destination's cursors to now: no history is replayed.
Hand findings to your ticketing system
The ITSM handoff is shipped, not planned. It posts the same signed JSON batch as a SIEM webhook, with a finding inside instead of an event.
Add the destination
Under ITSM handoff, select Add ITSM destination.
The dialog states what travels: the detection reference, its regulations, the owner and the due date — never prompt text and never a detected value.
Point it at your middleware
Set Webhook URL to your automation endpoint.
CID222 does not talk to Jira or ServiceNow directly, because your field mapping and credentials already live in your middleware.
Sign and route
Set Signing secret, add any Custom headers as one Name: value per line, and fill
Project / queue key, Issue type, Priority and Default assignee as needed.
The four defaults are passed through untouched so your receiver does not have to hard-code routing. Header values are encrypted at rest and never returned; the page lists only their names afterwards.
Test
Select Send test.
A toast reports Test finding delivered and your endpoint receives a real finding-shaped payload with sentinel values.
Note
Five header names are reserved and cannot be overridden: content-type, content-length,
host, x-cid-signature and x-cid-event-count.
Fields reference
What a CEF line looks like
| CEF field | CID222 value |
|---|---|
| Vendor, product | Always the literal strings CID222 and cid-core. |
| Version | The appliance's application version. |
| Signature | The event type. |
| Name | The event type, lower-cased with underscores replaced by spaces. |
| Severity | 0–10, from the destination's severity model. |
rt | When the event occurred, in epoch milliseconds. |
externalId | The event's own id. |
cat | The stream. |
suid, suser, cs1 | Tenant, user and session, when known. |
src | The request's source address, on v2 destinations. |
act | The action taken, when there is one. |
The syslog facility is fixed at local4 and is not configurable. The priority follows the CEF severity: 9 and above become critical, 7 and above warning, 4 and above notice, everything else informational.
What a webhook body looks like
One POST carries a batch: {"events":[…]}, where each entry is a flat JSON object with
source, stream, id, occurred_at, signature, name, severity, tenant_id, user_id
and session_id, followed by the event's own extension keys. ocsf replaces that envelope with
OCSF v1.8 class objects.
Delivery behaviour
| Property | Value |
|---|---|
| Export cycle | Every 30 seconds by default (SIEM_EXPORT_INTERVAL_MS). |
| Batch size | 200 events, up to five batches per cycle. |
| Retry | Per cycle, not per request: 1, 2, 4, 8 minutes, capped at 15. |
| Delivery guarantee | At least once. The cursor advances only after a successful send, so a failure is retried rather than skipped — duplicates are possible, loss is not. |
| Degraded | After five consecutive failures, or when a backlog stops moving for 30 minutes (SIEM_EXPORT_DEGRADED_AFTER, SIEM_EXPORT_STALL_MS). |
Verify
- The destination row shows Forwarded (24h) climbing and Last error empty.
- Your collector holds the test event, and the row's Sequence is stamped. Count the events in a window in your SIEM and compare with the sequence range: a shortfall means events were lost between the appliance and the collector. A gap is never expected.
- Take the collector offline. Within a few cycles the row is marked Degraded and Event
logs records
SIEM_EXPORT_DEGRADEDwith the reason and the consecutive-failure count. - Bring it back. The next successful cycle records
SIEM_EXPORT_RECOVERED, and the backlog is delivered rather than skipped. - For a signed webhook, recompute HMAC-SHA256 of the raw body with your secret and compare it
with the
X-CID-Signatureheader.
If it fails
- The page will not open, or every call returns
FEATURE_NOT_LICENSED→ SIEM export is an Enterprise capability. See Licence tiers. - config.protocol must be one of udp, tcp, tls or config.format must be one of cef, json,
ocsf → an unsupported value. The webhook format list is only
jsonandocsf. - config.url must be an http(s) URL → the webhook URL has no scheme.
- An ITSM destination subscribes to the "findings" stream only or The "findings" stream is delivered by an ITSM destination, not a SIEM one → the two kinds of destination cannot share streams.
- "…" is set by the gateway and cannot be overridden → you added one of the five reserved header names.
- Send test shows a raw connection error such as a refused connection or a syslog timeout → the appliance cannot reach the collector. The test surfaces the transport's own words.
- The row is Degraded with the collector kept refusing delivery → the endpoint is rejecting the batch. Check its status codes; anything outside 2xx is a failure.
- The row is Degraded with a backlog stopped moving → nothing has been delivered for 30 minutes although events exist.
- Cursor lag is growing but the row is not stalled → the gateway is quiet, not blocked. Lag only means a backlog when the destination is also marked stalled.
- A destination receives nothing although events are visible in All detections → check Severity floor, Event types (opt-in) and the tenant scope. Suppressed events are counted in Suppressed (24h).
Next steps
- All detections — the same records, queryable on the appliance.
- Event logs — the security and audit streams at their source.
- Data retention — how long those records survive locally once they are exported.